Reliable power for a sustainable world
Vietnam
Login
Language
Search
Login
Các sản phẩm
UPS
ON LINE UPS
Sentinel Pro
(700 - 3000 VA)
Sentinel Rack
(1.5 - 3 kVA)
Sentinel Dual (Low Power)
(1000 - 3000 VA)
Sentinel Dual SDU
(4 - 10 kVA)
Sentinel Tower
(5 - 10 kVA)
Sentryum
(10 - 120 kVA)
Multi Sentry
(160 - 200 kVA)
Multi Power
(45 - 294 kVA)
Multi Power2
(500 - 1600 kVA)
Sentryum Rack
(20 - 160 kVA)
Master MPS
(10 - 200 kVA)
NextEnergy NXE
(250 - 800 kVA)
Master HE
(100 - 800 kVA)
Master HP
(100 - 600 kVA)
Master HP UL
(65 - 500 kVA)
Master Industrial
(30 - 80 kVA)
Master FC400
(30 - 125 kVA)
Line interactive
Net Power
(600 - 2000 VA)
Vision
(800 - 2000 VA)
Vision Rack
(800 - 1100 VA)
Vision Dual
(1.1 - 3 kVA)
VFD Type
iPlug
(600 - 800 VA)
iDialog
(400 - 1600 VA)
iDialog Rack
(600 - 1200 VA)
Special solutions
Lithium Battery Solutions
SuperCaps UPS
CPS
CSS Sentinel Tower
(3 - 5 kVA)
CSS Sentryum
(6 - 120 kVA)
CSS Master
Các hệ thống chuyển đổi
Multi Pass
Multi Switch
Multi Switch ATS
Multi Socket PDU
Master Switch Single Phase
Master Switch Three-phase
Phần mềm & Kết nối
PowerShield³
PowerNetGuard
NetMan 208
Environmental sensor
MultiCom 302
MultiCom 352
MultiCom 372
MultiCom 384
MultiCom 411
MultiCom 421
Multi I/O
MultiPanel
Communication card adapter
Search products by areas of application
Use the areas option to go direct to the products that best suit your specific needs for power, backup time, and standards. Simply select the area of interest to view the full list of relevant products.
Sự săn sóc
Dịch vụ UPS
Đội ngũ TEC
Hỗ trợ
Tải xuống
HỎI ĐÁP
Hỗ trợ khách hàng
Vulnerability disclosure
Nhóm
Tập đoàn Riello Elettronica
Các giá trị thương hiệu
Energy and Sustainability
Riello UPS và Ducati Corse
Riello UPS and Aruba.it Racing - Ducati
Công nghệ và R & D
Các tài liệu tham khảo
Các sự kiện
Các tin tức mới
Liên lạc
Địa chỉ và liên lạc
Yêu cầu thông tin
Job Opportunities
Tải xuống
HỎI ĐÁP
Hỗ trợ khách hàng
Vulnerability disclosure
HỎI ĐÁP
Hỗ trợ
>
HỎI ĐÁP
Tìm hiểu kiến thức cơ bản
Search
Choose an option
Installation
Software
Hardware
Technology
UPS Maintenance
Power Quality
Search
Clear
All
Can I add more UPS modules to the system when my load increases?
Yes, the MST, MPS and MHT ranges employ a plug and play parallel system that allows additional units to be added to an existing system at a later...
Considerations when choosing a UPS and Generator combination?
It is usually beneficial to deal with one supplier for both items as this eliminates the potential conflict if the equipment does not work well...
What is a Brownout?
A brownout, sometimes also called a ‘sag’, is a "dip" in the voltage level of the electrical line. When a brownout occurs,...
What is a Blackout?
A blackout is when the power totally fails. The damage that a blackout causes to your system depends a great deal on its timing. If the system is...
What Is A UPS Factory Witness Test?
Witness testing for UPS systems takes place prior to full site installation and commissioning. It simulates real-life...
What Do The Different Emergency Response Times For UPS Repairs Mean?
Emergency Response Times when there’s a fault or failure with an uninterruptible power supply should be clearly spelled out in the...
What’s The Difference Between A Voltage Sag And A Surge?
Sags and surges both relate to short-term fluctuations in the mains power supply voltage. A Sag is a dip below the...
What is a Bypass Switch?
Static Bypass switches are used to bypass the UPS normal operation, in cases of high inrush or fault conditions. Manual bypass switches are an...
Cascade or Parallel redundancy?
UPS systems can be designed to operate in parallel to increase reliability (redundant systems) or to increase load handling capability (full...
When would I need a Generator?
Generators are usually used where there is likelihood that the load cannot be off for any length of time or in areas where the mains supply is...
←
1
2
3
4
5
6
→